Main technical parameters
Glass material
|
Tempered glass
|
Cabinet material
|
Stainless steel
|
Disinfection method
|
Ozone + UV
|
Feature
|
Ozone deodorization, drying,
Dehumidification, disinfection, sterilization |
Voltage frequency
|
220V~50Hz |
Rated input power |
300W |
600W |
Cabinet capacity and dimensions
|
350L(600*515*1755mm) |
700L(1200*515*1755mm) |
Cabinet temperature
|
48°C±10°C |
operate time |
0-90 minutes |
Disinfection method |
Ultraviolet + ozone
|
|
product size |
600*515*1755
|
1200*515*1755
|
Each layer of load |
8kg |
Number of shoes can be accommodated
|
12/24 pairs |
Usage scenario |
Home, hotel, sauna, hot spring |
Product characteristics
1, vertical cabinet, beautiful and generous
2, microcomputer control technology, easy to operate, equipped with automatic temperature control and constant temperature function.
3, can adjust the disinfection time 0-90 minutes.
4,Two-star standard, can kill stubborn viruses, germs
Operation method
1, before use should first check whether it meets the power supply voltage and power requirements of the machine.
2. Place the shoes that need to be disinfected and cleaned neatly on the shelf. Each layer can not exceed 2/3 of the space, otherwise it will affect the temperature cleaning effect.
3, plug in the power supply, press the power switch, the power indicator light, indicating standby power supply
4, the appropriate disinfection time can be adjusted within the range of 0-90 minutes, clockwise adjustment increases, and vice versa
5, start the disinfection switch, then the disinfection cabinet for automatic disinfection procedures
6. If the disinfection work is stopped, please press the power switch to reset the power indicator to turn off and the disinfection cabinet is finished.
Special attention
The installation and use of the product around the ventilation and dry, behind and around the safety material must be more than 100mm.
Tips: When the product does not work, be sure to disconnect the disinfection cabinet input power to ensure electrical safety.
warn
1, must use the specification of safe grounding power socket, and in line with national standards.
2, in the working process, the cabinet door can not be opened, otherwise there will be ozone leakage.
3, disinfection cabinet work after 30 minutes, to open the door, so as not to affect the disinfection effect, careful high temperature hot hands.
4, it is strictly prohibited to disinfect the shoes that are not clean and have residual water, otherwise it will corrode and damage the disinfection cabinet.
Notice they are just some part of our prodcuts, we support customized.