Discriptions:
Stainless steel,1200*435*1910mm
Hold 36-pair Shoes
Voltage:220V/50-60Hz
Power:350W,
Ozone generation:200mg/h
Function:
ozone deodorization, Drying,
Dehumidification
Button Explain
Power
(1) "Power" Button
After connecting the power,press the button,will have buzzer chirping sound,
coming into standby mode;press the button again,system will close and the screen
display the time.
(2) "Start" Button
After power connected at the standby model,press this button program begin
running;press again,the program will stop running.
(3) "Set up" Button
When system is shut down,press this button,can switch back and forth between
hour and minute,then you can set up the time.
(4) Left Arrow Button
Setting status,press this key time will reduce,press it for 1.5 seconds long,time
will decrease cyclically.
(5) Right Arrow Button
Setting status,press this key time will increase,press it for 1.5 seconds long,time
will increase cyclically.
Detailed Photos
Program Description
(1) Intelligence program
Press the power button to enter standby mode,the default is intelligence program,
the default time of this program is 90 minutes.Press the set up key and enter the
setting status,press the left/right arrow keys to adjust the running time of program.
(2) Dehumidification and mouldproof
Press the left/right arrow keys at standby mode to choose dehumidification program,
the default time is 90 minutes.Press the set up key and enter the setting status,then
press the left/right arrow keys to adjust the time in the range of 10~180 minutes.
(3) Sterilization deodorization
Press the left/right arrow keys at standby mode to choose sterilization deodorization
program,the default time is 60 minutes.Press the set up key and enter the setting status,
then press the left/right arrow keys to adjust the time in the range of 30~90 minutes.
(4) Timing start
Press the left/right arrow keys at standby mode to choose timing start program,
the default time is "6:00 AM" .Press the set up key and enter the setting status,press the
setting key to switch between hour and minute.When flashing,press the left/right arrow
keys to adjust the hour or minute.
Alarm Instructions and Elimination Methods
(1) E1 Alarm
System running,display E1 system alarm
Cause analysis:(1)the door is not closed well (2)system failure
Elimination method:(1)lock the door (2)contact our maintenance center
(2) E3 Alarm
Display E3
Cause analysis:temperature sensor failure
Elimination method:contact our maintenance center